Final bone height exhibited a moderately positive correlation with residual bone height (r = 0.43, P = 0.0002). A negative correlation of moderate strength was observed between residual and augmented bone heights (r = -0.53, p = 0.0002). Sinus augmentations performed trans-crestally show a pattern of similar outcomes among experienced clinicians, indicating minimal inter-operator variability. The pre-operative residual bone height, as assessed by CBCT and panoramic radiographs, yielded comparable results.
The mean residual ridge height, as measured pre-operatively via CBCT, amounted to 607138 mm. This finding was closely aligned with the 608143 mm measurement gleaned from panoramic radiographs; the difference proved statistically insignificant (p=0.535). All patients experienced a smooth and uncomplicated postoperative healing process. A complete and successful osseointegration of all thirty implants was noted at the six-month evaluation. The mean final bone height across the group was 1287139 mm (1261121 mm for operator EM and 1339163 mm for operator EG), with a p-value of 0.019. Furthermore, the average post-operative bone height gain was 678157 mm. This corresponded to 668132 mm for operator EM and 699206 mm for operator EG, achieving a p-value of 0.066. Final bone height showed a moderate positive correlation with residual bone height, with a correlation coefficient of 0.43 and a p-value of 0.0002, signifying statistical significance. Residual bone height displayed a moderate negative correlation with augmented bone height, resulting in a statistically significant finding (r = -0.53, p = 0.0002). The outcomes of sinus augmentation procedures, performed trans-crestally, are consistent and exhibit minimal inter-operator differences amongst experienced clinicians. Pre-operative residual bone height evaluations were strikingly similar on both CBCT and panoramic radiographs.
The absence of teeth, congenital in origin and potentially syndromic, in children can give rise to oral dysfunctions, with the possibility of general and socio-psychological complications arising. The case involved a 17-year-old female with severe nonsyndromic oligodontia, characterized by 18 missing permanent teeth, and a class III skeletal configuration. Achieving both functional and aesthetically pleasing outcomes in temporary rehabilitation during development and lasting rehabilitation in adulthood proved to be a considerable challenge. A novel method for managing oligodontia, as outlined in this case study, is presented in two distinct segments. Improving the large bimaxillary bone volume by utilizing LeFort 1 osteotomy advancement with concurrent parietal and xenogenic bone grafting will allow for the implantation procedure earlier in the future without affecting the growth of the adjacent alveolar processes. Prosthetic rehabilitation using screw-retained polymethyl-methacrylate immediate prostheses, alongside the maintenance of natural teeth for proprioception, seeks to determine the essential vertical dimensional changes needed, thus enhancing the predictability of both functional and aesthetic results. For managing cases similar to this one within the intellectual workflow, this article is suitable to be preserved as a technical note, detailing challenges encountered.
The infrequent but clinically pertinent issue of fracture within any dental implant component is a potential complication. Due to their inherent mechanical design, implants with small diameters are more susceptible to complications of this nature. This laboratory and FEM study aimed to compare the mechanical response of 29 mm and 33 mm diameter implants with conical connections, evaluating them under standard static and dynamic loads according to ISO 14801-2017. Finite element analysis was undertaken to contrast stress patterns in the tested implant systems while subjected to a 300 N, 30-degree inclined force. A 2 kN load cell was employed during static tests on experimental samples; the force was applied at a 30-degree angle with respect to the implant-abutment axis, using a lever arm measuring 55 mm. Fatigue tests, with diminishing loads at a 2 Hz frequency, were undertaken until three samples completed 2,000,000 cycles without any evident damage. Symbiont interaction In the finite element analysis, the abutment's emergence profile manifested as the area experiencing the highest stress levels; 5829 MPa for the 29 mm diameter implant and 5480 MPa for the 33 mm diameter implant complex. 360 Newtons was the mean maximum load for 29 mm diameter implants; 33 mm diameter implants, conversely, registered a mean maximum load of 370 Newtons. medical competencies Observations demonstrated that the fatigue limit was 220 N for one instance and 240 N for another. The 33 mm implants performed better overall, however the differences between the tested implants were considered to be clinically negligible. This is potentially a consequence of the conical design of the implant-abutment connection; this design pattern has been documented to yield low stress in the implant neck, thus reinforcing its resistance to fracture.
A successful outcome hinges on satisfactory function, pleasing aesthetics, clear phonetics, durable long-term stability, and a lack of complications. This case report describes a mandibular subperiosteal implant that has achieved a successful follow-up spanning 56 years. The long-term favorable outcome was the product of multiple contributing factors, including patient selection, rigorous adherence to anatomical and physiological principles, well-conceived implant and superstructure design, the skill of the surgical procedure, the implementation of appropriate restorative techniques, diligent oral hygiene, and a systematic re-care regimen. Intricate coordination and cooperation were evident between the surgeon, restorative dentist, laboratory personnel, and the patient's exceptional compliance in this case study. Thanks to the mandibular subperiosteal implant, this patient's formerly debilitated oral health was revitalized, moving them beyond the state of being a dental cripple. The most important element of this case is the fact that it represents the longest confirmed period of success in the history of any type of implant treatment.
Implant-supported bar-retained overdentures with cantilever extensions, subjected to heightened posterior loading, experience amplified bending moments on the implant abutments adjacent to the cantilever and increased stress within the prosthetic components. A new connection design for abutment-bar structures, implemented in this study, seeks to reduce unwanted bending moments and resulting stresses, achieving this by increasing the rotational freedom of the bar on its abutments. In order to alter the bar structure's copings, two spherical surfaces were integrated, their centers situated at the centroid of the coping screw head's upper surface. A four-implant-supported mandibular overdenture, having its design enhanced through a novel connection, was adapted into a modified overdenture. Finite element analysis was applied to both the classical and modified models exhibiting bar structures with cantilever extensions in the first and second molar locations. Similar analysis was undertaken for the overdenture models lacking these extensions, thus allowing a comprehensive comparison of their deformation and stress. To assess their durability, real-scale prototypes of both models, incorporating cantilever extensions, were constructed, mounted on implants embedded in polyurethane blocks, and put through fatigue tests. Implants from each model were subjected to a pull-out test, assessing their performance. The new connection design improved the rotational freedom of the bar structure, significantly minimized the influence of bending moments, and reduced stress on both cantilevered and non-cantilevered peri-implant bone and overdenture components. The observed effects of the bar structure's rotational mobility on the abutments, as confirmed by our findings, underscore the critical role of abutment-bar connection geometry in design.
Establishing an algorithm for the management of dental implant-induced neuropathic pain, utilizing both medical and surgical interventions, is the objective of this study. Following the good practice guidelines of the French National Health Authority, the methodology was established; subsequently, the Medline database was searched for data. A preliminary draft of professional recommendations, based on qualitative summaries, has been compiled by a working group. Drafts, in succession, were altered by the members of a multidisciplinary reading panel. Scrutinizing a total of ninety-one publications, twenty-six were selected to form the basis of the recommendations. This selection included one randomized clinical trial, three controlled cohort studies, thirteen case series, and nine individual case reports. Neuropathic pain following implant placement necessitates a comprehensive radiological assessment, including a minimum of a panoramic radiograph (orthopantomogram) or a cone-beam computed tomography scan, to ascertain that the implant tip is positioned securely, exceeding 4 mm from the anterior loop of the mental nerve for anterior implants and 2 mm from the inferior alveolar nerve for posterior implants. The early, high-dose steroid protocol, potentially integrated with partial or complete implant removal preferably within 36 to 48 hours following implantation, is considered optimal. Minimizing the risk of chronic pain could be achieved through a combined pharmacological approach, incorporating anticonvulsants and antidepressants. When a nerve lesion is observed subsequent to dental implant surgery, treatment, encompassing possible removal of the implant (partially or fully) and early medicinal intervention, must begin within 36 to 48 hours.
The biomaterial, polycaprolactone, has shown expeditious results in preclinical bone regeneration trials. Nimodipine supplier This report, featuring two case studies from the posterior maxilla, is the first to report the clinical application of a customized 3D-printed polycaprolactone mesh in alveolar ridge augmentation. Two patients, whose cases necessitated significant ridge augmentation for dental implant procedures, were selected.